Chapter 6:

70

Simon XT TableTop Control Panel Installation Manual

Troubleshooting

This section provides information to help you diagnose and solve various
problems that may arise while configuring or using your UTC Fire & Security
product and offers technical support contacts in case you need assistance. (See
“Contacting us” on page 72.)

System status

• How do I clear Status (alarm memory)?

From a disarmed state press Status, listen to the status message, then press
Disarm.

• The panel displays and announces Siren 1 failure.

Turn the Hardwired siren supervision option off if a hardwired siren or sensor
is not connected. Check for the correct end-of-line resistor in HW1 I/O circuit.

• Panel displays and announces low battery.

Check that panel backup battery is connected. Check panel backup battery
voltage. If less than 5.4 volts, replace battery and clear system status
message.

Run a sensor test.

• The panel displays and announces RF jam.

The control panel has detected RF interference.

• The panel displays and announces that a sensor is open.

See “Sensors” on page 43.

• The panel displays Set time and announces system time is not set.

Set the system time.

Control panel

The panel displays and announces Invalid.

This sensor is already programmed. Delete sensor if not correctly
programmed.

Options (programmable by the homeowner)

• The panel does not beep.

Turn on piezo beeps option.

• Latchkey does not function.

Latchkey time is not set. Set latchkey time.