Chapter 4:
46
Simon XT TableTop Control Panel Installation Manual
Function
Default Description
Closing
reports
Off
Determines whether the panel sends closing reports to a central station
whenever the system is armed (on), or not (off). User number will be
reported as zone number. Keyfobs learned into zones 1 through 40 will
report as the zone they are learned into.
Dealer code = 44 Installer code = 45 Master code = 46
User code 1 = 47 User code 2 = 48 User code 3 = 49
User code 4 = 50 User code 5 = 51 User code 6 = 52
User code 7 = 53 User code 8 = 54 Duress code = 55
Force
armed
Off
Determines whether the panel sends a force armed report to a central
station if the user bypasses protesting sensors (indirect bypass) when
arming the system (on) or not (off).
AC power
failure
Off
Determines whether or not the panel sends AC power failure reports to a
central station after the programmed time expires. The time can be set
from 005 to 254 minutes.
•
When the panel is without AC power for 30 seconds, the panel LEDs
turn off.
•
When the panel is without AC power for the programmed time, an AC
power failure is reported.
•
The panel reports an AC power restoral when AC power returns to the
panel.
Low CPU
battery
On
Determines whether the panel sends a low CPU battery report to the
central station when the panel backup battery voltage drops
Sen alarm
restore
Off
Determines whether the panel reports sensor alarm restorals (on) or not
(off). Setting when restorals are reported:
1. Immediately after sensor is closed or restored after dial delay.
2. After siren timeout expires if sensor is restored.
3. When system is disarmed if sensor is restored.
24-hour
sensor
tamper
Off
Determines whether the system (armed or disarmed) goes into and
reports an alarm anytime a sensor tamper switch is tripped (on), or only
when the system is armed and a tamper switch of an armed sensor is
tripped (off).
Supervisor
y tamper
Off
Determines whether the panel sends supervisory reports to a central
station as a tamper (on) or a supervisory (off). This option is typically used
only in Europe where a supervisory condition is required to report as a
tamper.