Chapter 4:

48

Simon XT TableTop Control Panel Installation Manual

Timers

Table 18 below provides timer option details.

Table 18: Timers

Function

Default Description

Latchkey
time

Off

Determines whether the panel reports a latchkey alarm if the system is not
disarmed at a preset time between midnight and 11:59 p.m. (on). If the
latchkey feature is disabled (off), the panel will not report a latchkey alarm.

The system clock must be set for the latchkey feature to work.

Entry delay 030

seconds

Determines how much time the user has to disarm the system after
entering the armed premises through a designated delay door, before an
alarm occurs. Beeps sound during the entire delay time to remind the user
to disarm the system.

The entry delay can be set from 030 to 250 seconds.

Exit delay

060
seconds

Determines how much time the user has to leave the premises through a
designated delay door after arming the system. Beeps sound after arming
the system to remind the user to leave the armed premises. If a delay
door is opened after the exit delay expires, the entry delay begins. If the
user arms the system with no delay and opens a delay door after the exit
delay expires, an alarm occurs.

No activity
tm

Off

Determines whether the panel sends a no activity report to a central
station when the programmed time period elapses (on), or if the feature is
disabled (off).

No activity means control panel, remote handheld, and key -chain
touchpad buttons have not been pressed and sensors have not been
tripped within a specified period of time (except sensors in group 25).

The timeout can be set from 02 to 24 hours.

Autophone
test

Off

Determines whether the panel automatically performs a periodic phone
test (on) or not (off). The test interval can be from 001 to 254 days. The
time of day the panel performs the test is determined by supervisory time,
which must be turned on for this feature to work.

Supervisor
y time

12:00a
m

Determines when the panel reports supervisory conditions (sensor
failures) and automatic phone tests to the central station.

The panel clock must be set to the correct time for this option and the
automatic phone test to work correctly.

Alarm
cancel

006

Sets the time frame that determines whether the panel reports an alarm
cancel message to the central station. If the system is disarmed from an
alarm state within the programmed time, the panel sends an alarm cancel
message to the central station. An alarm cancel message is not reported if
the system is disarmed after the programmed time expires.

The time can be set from 006 to 255 minutes. When set to 255, the panel
always reports alarm cancel messages. Turning off this option disables
alarm cancel reporting.