Function

Default

Description

Sup protest

Off

Determines whether the panel protests arming if it has not
received a supervisory signal from any sensor 15 minutes before
arming (on) or not (off).

Note: This feature must be turned off for US installations.

Phone numbers

Table 12 below provides phone number option details.

Table 12: Phone numbers

Function

Default Description

Phone # 1

Blank

Lets you program up to a 26-digit central monitoring station
receiver/voice event notification phone number for monitored systems.
Phone digits can be 0-9, *, #, or a pause (P).

To delete the phone number, press Disarm while editing a phone digit.
To add a pause to the phone number press Bypass. Pressing Enter is
required if you enter fewer than 26 digits.

Phone # 2

Blank

Phone # 3

Blank

Phone # 4

Blank

Downloader #

Blank

Lets you program up to a 26-digit phone number for the Enterprise
Downloader.

Phone options

Table 13 below provides phone option details.

Table 13: Phone options

Function

Default

Description

Man phone test

On

Determines whether the user can perform a manual
communication test to verify communication to a central
station/voice dial (on), or not (off). If you have all 4 phone #
programmed it should send a test report to all 4 before showing
that test is okay.

FTC

On

Determines whether the panel and interior sirens sound trouble
beeps if it is unable to successfully send a report to a central
station (on) or not (off).

DTMF dial

On

Determines whether the panel uses DTMF (on) or pulse (off) for
dialing programmed phone numbers.

300 bps enabled

On

Determines whether the baud rate used by the panel for central
station communication is 300 bps (on) or 110 bps (off).