Latchkey is not enabled. Enable latchkey by pressing Motions twice.

The phone number is not programmed properly. Reprogram the phone
number.

System time is not set. Set system time.

Sensors

• A sensor does not work.

Make sure the battery is good and installed correctly.

Check for interference from metal objects. Move or rotate the sensor.

• Door or window is closed, but the panel announces it is open.

Be certain the arrow on the magnet and the guide line on the transmitter are
aligned and within 1/4 inch of each other. The sensor tamper switch may be
open (cover off).

• Motion sensors go off continuously.

Be sure the sensor is mounted on a solid surface and the viewing field is free
from sources of changing temperature. The sensor tamper switch may be
open (cover off).

• Motion sensor does not respond to motion.

Make sure the sensor battery is good and installed correctly. Wait two
minutes after installing a new battery to test the sensor.

Adjust the sensor mounting.

Leave the area for three minutes, then retest.

The environment is too hot or too cold. Outdoor sensors operate between 32
and 120°F (0 and 49°C).

Dirt or dust may be causing the problem. Wipe the sensor with a clean, damp
cloth.

X10 modules

• All lamp modules or siren not working.

Be sure the panel transformer is plugged into an outlet that is not controlled
by a switch.

Check that the panel is powered using the line carrier power transformer.

Make sure the housecode was programmed correctly.

• One lamp module or siren is not working.