Central station communication – Interlogix Simon XT Tabletop Installation Manual User Manual

Page 71

Advertising
background image

Chapter 5:

Simon XT TableTop Control Panel Installation Manual

65

System Function

Phone command

Specific light off

#

– <unit_num>.

All lights on

*

– *

All lights off

#

– #

System status

0

Audio verification

5 + X (X = a command from Audio Verification
Set)

Terminate session

9

Central station communication

After performing sensor and communication tests, check that the system is
reporting alarms successfully to the central station. Table 31 below provides a list
of sensor/user report codes.

To test communication with the central station, do the following:

1. Call the central station and tell the operator that you will be testing the

system.

2. Arm the system.

3. Test each of the wireless panic buttons and trip at least one sensor of each

type (fire, intrusion, etc.) to verify that the appropriate alarms are working
correctly.

4. When you finish testing the system, call the central station to verify that the

alarms were received.

Table 31: Sensor/user report codes

Arm or disarm from

Reports as user

Panel or remote touchpad

0

Keyfob

1 to 40 (sensor number)

Panel aux panic

41

Panel tamper

42

Panel police panic

43

Panel fire panic

44

Dealer access code

44

Installer access code

45

Master code

46

Advertising