50

Simon XT TableTop Control Panel Installation Manual

Function

Default Description

Panic
alarms

On

Determines whether the panel panic buttons (police, auxiliary, and fire)
activate alarms when pressed (on) or not (off)

Remote
TP arm

Off

Determines whether keyfobs and remote touchpads can disarm the
system only during exit and entry delays (on) or arm and disarm the
system anytime (off). If this option and Keyfob no delay are on, users
cannot enter and/or disarm using remote touchpads without causing an
alarm.

System options

Table 20 below provides system option details.

Table 20: System options

Function

Default Description

RF jam
detect

Off

Determines whether the panel checks for and reports RF interference/jam
to the central station (on) or not (off). If this option is on and the panel
receives a constant 319.5 MHz signal, the panel reports the condition to
the central station. If this option is off, the panel does not detect an RF
jam.

Demo
mode

Off

Determines whether the panel operates as a demonstration model (on) or
a standard panel (off).

Turning on this feature disables low battery supervision and allows the
microphone to remain on continuously during an AVM session. With
option on panel is not testing battery supervision.

HW 1
function

1

The setting for this option determines how the HW1 I/O output will
function.

Off = No output

1 = Interior siren output

2 = Output activated when armed

3 = Output activated when disarmed

4 = Fail to communicate output; activates when fail to communicate
condition occurs (fail to communicate must be on)

5 = Alarm output activated when panel is in alarm.

24-hour
clock

Off

Determines whether the panel uses a 24-hour clock (on) or 12-hour clock
(off).

Siren options

Table 21 on page 51 provides siren option details.

Advertising