CAUTION

Condensate is mildly acidic (pH=5), and may harm some floor drains and/or pipes, particularly those that are

metal. Ensure that the drain, drainpipe, and anything that will come in contact with the condensate can withstand

the acidity, or neutralize the condensate before disposal.

Damage caused by failure to install a neutralizer kit

or to adequately treat condensate will not be the manufacturer’s responsibility.

Contact Laars to order Kit# A2123601

__________________________________________________________________________________________

Figure 13. DHW Connections with Anti-Scald Valve

and Flow Restrictor.

6.7 Condensate Drain

A condensate drain trap is built into the Mascot LX.
Connect a 3/4” PVC pipe between the drain connection

and a condensate neutralizer before entering drainage

system.
The condensate drain and included trap must be

installed. When a condensate pump is not used, the

tubing must continuously slope downward toward the

drain with no spiraling.
Consult local codes for the disposal method.