Mascot LX Boilers and Water Heaters

Page 35

Laars SIT Parameters

Page 2

P49

CH Priority time over DHW

0 min

SWITCHOVTCH

P50

DHW Priority time over CH

55 min

* displayed as seconds

SWITCHOVTHW

P51

DHW tank setpoint

180 ° F

HWTNKSETP

P52

Stop DHW tank demand offset

0 ° F

HWDEMSTOP

P53

Start DHW tank demand offset

6 ° F

HWDEMSTART

P54

Block DHW demand (combi) offset

12 ° F

HWREGBLO

P55

Unblock DHW demand (combi) offset

20 ° F

HWREGHYS

P56

Minimum user setting DHW set point

60 ° F

CMINHW

P57

Maximum user setting DHW set point

140 ° F

CMAXHW

P58

Frost protection s tart pump temperature

45 ° F

FROSTPMP

P59

Frost protection start burner temperature

37 ° F

FROSTBURN

P60

Frost protection stop burner hysteresis

5 ° F

FROSTHYS

P61

Low outdoor air temperature for heat curve

25 ° F

HC1AX

P62

High setpoint for heat curve

180 ° F

HC1AY

P63

High outdoor air temperature for heat curve

70 ° F

HC1BX

P64

Low setpoint for heat curve

120 ° F

HC1BY

P65

Outside temperature disabling CH demand

90 ° F

HC1OUTLIM

P66

Outside temperature disabling CH hysteeresis

5 ° F

HC1OUTHYS

P70

Minimum user setting CH set point

32 ° F

CMINCH

P71

Maximum user setting CH set point

190 ° F

CMAXCH

P72

Block offset CH demand

10 ° F

CH1BLO

P73

Block hysteresis CH demand

20 ° F

CH1HYS

DH

W

SE

TTIN

G

S

TEM

P.

SE

TTIN

G

S

FR

O

ST P

RO

TE

CTIO

N

&

OU

TD

OOR

R

ES

ET

8.5 SERVICE Mode

The Mascot LX Series of appliances has been

designed with a SERVICE Mode of operation

intended for servicing and troubleshooting of the

unit by a Mascot LX trained service technican.
‘SERVICE' Mode can be activated by pressing

and holding the 'Select/OK' button and ‘Up Arrow’

simultaneously for five seconds. With an active call

for heat, the boiler will light and run at 100% of firing

rate. The boilers input can be adjusted in 20% rate

increments by pressing the ‘Up’ or ‘Down’ Arrows. You

can also toggle between Maximum Rate and Minimum

Rate by pressing the 'Select/OK' button. To exit

SERVICE Mode depress and hold the 'Select/OK' button

for five seconds.

Table 16. Installer Parameters (part 2)

8.6 Modulation Control

The control uses a PID algorithm to adjust the firing

rate of the boiler as the control point is approached.

The goal of the control is to operate at a minimum

firing rate to match the load on the appliance.

8.7 Pump Control

The boiler pump is active anytime there is a call for

heat applied to the control. When there is a central

heat call the system pump relay is active. If there

is a DHW call while the central heat call is active

the system pump turns off. This happens because of

domestic hot water priority, which forces the control

to satisfy the domestic water demand prior to the

hydronic demand. When the last heat demand is

satisfied the boiler pump enters an overrun time.

NOTE: There must be an active call for heat given

to the appliance for Service Mode to allow the

boiler to start. When the Service Mode is exited,

the boiler will continue to run until the call is either

satisfied or removed.

will stop.

The parameter value will return to the previous

setting if you press the Cancel button.

Otherwise, Exit INSTALLER Mode by pressing

and holding 'Select/OK' for 3 seconds.