LAARS Mascot LX MLXC 175 MBH - Install and Operating Manual User Manual

Page 46

Advertising
background image

LAARS Heating Systems

Page 42

SECTION 11.

Maintenance

WARNING

Disconnect all power to the appliance before

attempting any service to the appliance. Contact with

electricity can result in severe injury or death.

11.1 System Maintenance

(yearly, unless otherwise noted)
1. If a strainer is employed in a pressure reducing

valve or the piping, clean it every six months.

2. Inspect the venting system for obstruction or

leakage at least once a year. Periodically clean the

screens in the vent terminal and combustion air

terminal (when used).

3. Keep the appliance area clear and free from

combustible materials, gasoline, and other

flammable vapors and liquids.

4. If the appliance is not going to be used for extended

periods in locations where freezing normally

occurs, it should be isolated from the system and

completely drained of all water.

5. Low water cutoffs, if installed, should be checked

every year. Float type low water cutoffs should be

flushed periodically.

6. Inspect and clean the condensate collection system

yearly.

7. When a means is provided to neutralize condensate,

ensure that the condensate is being neutralized

properly.

8. Removal of burner and inspection of combustion

coil and flue passages is required at least once a

year. Clean with a soft bristle brush / vacuum or

wash with water if necessary. Sooting and buildup

on the coils is an indication of improper set up and

poor combustion. Determine the cause and make

corrections.

9. Inspect the vent system and air intake system, and

ensure that all joints are sealed properly. If joints

need to be resealed, completely remove existing

Garlock sealing material, and clean with alcohol.

Apply new sealing material, and reassemble.

11.2 Appliance Maintenance and

Component Description

Use only genuine LAARS replacement parts.

Mascot LX gas and electric controls are engineered for

long life and dependable operation, but the safety of

equipment depends on their proper functioning. Only

a qualified service technician should inspect the basic

items listed below every year:

a. Appliance control

f. Flow switch

b. Automatic gas valve g. Low water cutoff

c. Pressure switches

h. Burner

d. Blower

i. Heat exchanger

e. Pump

11.2.1 Burner

Check the burner for debris. Remove the blower

assembly to access the burner. Remove the 4 bolts

connecting the blower Pull burner up and out. Clean

burner, if necessary, by blowing compressed air from

the outside of the burner into the center of the burner,

and wipe the inside of the burner clean with glass

cleaner. A dirty burner may be an indication of improper

combustion or dirty combustion air. Determine the

cause, and correct. If damaged, replace the burner gasket

when replacing the burner.

NOTE: When installing the burner, make sure the flange

is aligned with the mating surface, as each is keyed to

control fit.

11.2.2 Appliance Control

Mascot LX has an integrated control that incorporates

manual reset high limit control, operating temperature

control, modulating control, ignition control, outdoor

reset control, pump control and many other features. If

any of these features are thought to be defective, please

consult the factory for proper trouble shooting practices

prior to replacing the control. If control replacement is

required, turn off all power to the appliance and shut off

all manual gas valves to the appliance. Remove the front

door to the appliance and the control panel plastic bezel.

Remove all wire connections from the control board.

The control board connections are keyed to only allow

connection in the proper location, but proper handling

techniques should be used to avoid damage to the

wiring or connectors. To remove the control push in on

the two tabs on the left side of the board to unlatch the

clips from the control panel. Rotate the control around

ATTENTION

Au moment de l'entretien des commandes, étiquetez

tous les fils savant de les débrancher. Les erreurs de

câblage peuvent nuire au bon fonctionnement et être

dangereuses. S'assurer que l'appareil fonctionne

adéquatement une fois l'entretien terminé.

CAUTION

Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and

dangerous operation. Verify proper operation after

servicing.

Advertising