30 v35 -28, 5 status commands -28, 1 equipment -28 – Carrier Access Access Bank II SNMP User Manual

Page 173: 5 status commands

Advertising
background image

14-28

9/24/01

14.4.4.30 v35

Use the v35 command to configure parameters for the V.35 data port to be accessed by the SNMP
manager via RFC-1659.

14.4.5 Status Commands

14.4.5.1equipment

Use the equipment command to display the hardware equipment configuration within the Access
Bank.

Operations

Type

Comments

To set the circuit ID to
“V.35 - 1”

v35 circuitid “V.35 - 1”

Sets the Circuit Id for the V.35 port

To set clock inversion to
receive clock inverted

v35 clkinv rx

Sets the receive clock to be inverted.

To set CTS to follow
RTS signal

v35 cts rts

Sets CTS to follow RTS signal

To set data inversion

v35datainv invert

Sets the V.35 data to be inverted.

To set receive clock
source to be internal

v35 rxclk internal

Sets thte system to use the Internal
Clock.

To set the speed to be
nx56

v35 speed nx56

Sets the data raste to Nx56 KBps

To display Help

v35 ?

Operations

Type

Comments

To display the equipment
list

equipment

Displays a list of the current installed
hardware and Firmware revision
levels.

Advertising