5 setting the transmit and receive levels – Carrier Access Access Bank II SNMP User Manual

Page 91

Advertising
background image

Battery Reversal FXS & Dial Pulse Origination Card

9-18

9/24/01

Figure 9-2: Dial Pulse Origination (DPO) for DID Transport

9.5 Setting the Transmit and Receive Levels

The transmit and receive levels for each BRFXS/DPO voice frequency channel can be set between 0
and -9 dB using twelve 6-position DIP switches (CH1 - CH12) on top of the circuit board card (see
Figure 9-3). Each analog channel uses a bank of six DIP switches, with three for transmit and three
for receive. Operation of each set of three switches in additive. For example, setting switch 1 (-2 dB)
and switch 2 (-3 dB) to OFF for any given channel selects a receive loss of -5 dB. The default setting
for the transmit level is -3 dB; for the receive level it is -6 dB. The default settings are appropriate for
most applications.

Table 9-1: Transmit and Receive Attenuation Switch Values

Switch

Setting

Transmit Switch Position Loss

Receive Switch Position Loss

1

2

3

4

5

6

On

0

0

0

0

0

0

Off

-2

-3

-4

-2

-3

-4

Called Party's

Direct Extension

DPO*

DPT*

PBX

DID
Lines

Direct Inward Dial (DID)

Leased T1

* Use CAC's FXO/DPT 12-Channel
voice card

Remote LEC

Switch

DID
Lines

Advertising