Top view, Tip & ring connector – Carrier Access Access Bank II SNMP User Manual

Page 29

Advertising
background image

2-4

9/24/01

Figure 2-2: Access Bank II - SNMP Top Cover Installation Guide

Top View

T1 LEDs (PER SPAN)

STATE

MEANING

OFF

Loss of T1 signal, no pulses

received

GREEN

Nodal Switch is in frame with

frame bit error rate <10E -5

FLASHING

Nodal Switch is in frame, but

GREEN

frame bit error rate exceeds 10E-5

RED

AIS (unframed all ones)

received from the T1 line

FLASHING

Nodal Switch is not framed to

RED

the T1 line but no AIS is received

YELLOW

Yellow alarm received from the T1 line

FLASHING

BPV errors received on the T1 line

YELLOW

that are not due to B8ZS line coding

V.35 STATUS LED

STATE

MEANING

OFF

No T1 channels assigned to V.35

port

GREEN

CD and RTS active. T1 channels

assigned and operable

FLASHING

V.35 in loopback to equipment

GREEN

RED

CD is inactive because assigned
T1 is inoperable

YELLOW

CD active RTS inactive

FLASHING

V.35 in loopback to T1 line

YELLOW

T1 TEST LEDs (PER SPAN)

STATE

MEANING

GREEN

Normal operation. Trunk processing,

self test, and network loopback

inactive

FLASHING

T1 self test local loopback

GREEN

passed

RED

T1 self test local loopback

failed

YELLOW

Channels held in trunk processing

for this T1

FLASHING

Network loopback active for this

YELLOW

T1

T1 JACK R48CPIN ASSIGNMENT

1

R1 - Receive ring from T1 line

2

T1 - Receive tip from T1 line

4

R - Transmit ring to T1 line

5

T - Transmit tip to T1 line

7&8

Ground for T1 cable shields

NODAL SWITCH CONTROL SWITCHES

SWITCH

FUNCTION

OFF

ON

SYSTEM SETUP

1

local/remote

local

remote

2

alarm cutoff

enable alarm

disable alarm

3

Option 1

4

Option 2

T1 SPAN 1 SETUP

1

Self test 1

off

on

2

Network loopback 1

off

on

3

T1 framing 1

Superframe

Extended

(SF) (also

superframe

called D4)

(ESF)

4

T1 line coding 1

Alternative

B8ZS

Mark
Inversion (AMI)

5

CSU on/off 1

Detect loop

Reject CSU

code (normal)

loopcode

T1 SPAN 2 SETUP

6

Self test 2

Off

On

7

Network loopback 2

Off

On

8

T1 framing 2

Superframe

Extended

(SF) (also

superframe

called D4)

(ESF)

9

T1 line coding 2

Alternative

B8ZS

Mark
Inversion (AMI)

10

CSU on/off 2

Detect loop

Reject CSU

code (normal)

loopcode

NODAL SWITCH ANALOG LEVELS

SWITCH

FUNCTION

LEVEL

Six switches Transmit =

Off adds loss

per channel

Analog to T1
Receive =

All switches off =

T1 to analog

0 dB

1

Receive -2 dB Off = 2 dB lower

2

Receive -3 dB Off = 3 dB lower

3

Receive -4 dB Off = 4 dB lower

4

Transmit -2 dB Off = 2 dB lower

5

Transmit -3 dB Off = 3 dB lower

6

Transmit -4 dB Off = 4 dB lower

NODAL SWITCH ANALOG SIGNALING

SWITCH

LABEL

FUNCTION

Four

Four switches

Off adds loss

switches

set card sig-

per card

naling options

Consult manual for

for all 12 chan signaling option settings

per voice card type

1

Option A

Off = normal FXS

2

Option B

Off = normal FXS

3

Option C

Off = normal FXS

4

Trunk proces-

When TP or test:

sing (TP)

On = loop busy

Busy/Idle

Off = loop idle

BACKPANEL CHANNEL LEDs

COLOR

PER CHANNEL FUNCTION

OFF

Idle (FXS ground start , tip open

GREEN

Incoming call (FXS loop start

RED

Outgoing call

YELLOW

Answer (taking) condition

Tip & Ring
Connector

10 BASE T ACTIVITY LED

STATE

MEANING

OFF

No data RX/TX

GREEN

RX/TX Data

RED

Collision detected

10 BASE T LINK LED

STATE

MEANING

OFF

No signal received

GREEN

Validate connection

Advertising