Groups menu reference, 8 add page – Lab.gruppen PLM 20K44 User Manual

Page 183

Advertising
background image

178

Lake Controller Operation Manual Rev 1.5.4

Groups Menu Reference

When GANG XOVER/AUX is active on a Group containing crossover Modules, the crossovers, HPF/LPF,
and auxiliary channels of all Modules in the Group are synchronized. A change made in one Module will
be reflected in all Modules of that Group.

When Gang HPF/LPF is active on a Group containing Mesa EQ Modules, the HPF/LPF will be linked on
all Modules in the Group.

To gang the crossover or HPF/LPF of all Modules in a Group, perform the following steps:

1. Assign the Modules to a Group. All Modules must be of the same crossover type, such as Classic

3-Way (CL3way), for example.

All Modules must be of the same Module type,

such as a Classic 3-Way (CL3way), for example.

2. From the GROUPS menu, tap GANG.

3. Tap the Module on the scroll bar to select which Module’s settings will be transferred to all other

Modules in the Group.

4. Tap GANG XOVER/AUX (Contour Modules) or GANG HPF/LPF (Mesa EQ Modules).

5. Tap YES to the warning message.

Only the XOVER/AUX/HPF/LPF and associated

OUTPUT EQ data is ganged. LEVELS data and

INPUT EQ (PEQ/GEQ) cannot be ganged. Use

Group EQ/LEVELS to control multiple Modules.

To synchronize all data across multiple Modules,

you can use the powerful SUPER MODULE

feature. Refer to section 8.8 for details.

10.8 Add Page

The ADD PAGE function is always available from the GROUPS menu and creates additional pages that help
manage large systems with many Module and Group icons.

Advertising
This manual is related to the following products: