4 i/o configuration view mode options, My8-lake reference and operation – Lab.gruppen PLM 20K44 User Manual

Page 285

Advertising
background image

280

Lake Controller Operation Manual Rev 1.5.4

MY8-LAKE Reference and Operation

Figure 22-5: Analog Output Reference Options

The limiter compensation is active only on Host input channels (Host returns) from Contour Module outputs;
outputs from Mesa Modules, or other output types will not have this compensation applied.

22.4 I/O Configuration View Mode Options

22.4.1 Simplified View (not yet implemented)

The MY8-LAKE provides a simplified I/O routing view by default for Mesa Mode that allows simple configu-
ration of all input and output parameters. In Simplified View, the following functionality differs compared to
normal Lake Controller operation:

The Digital Clock Configuration screen is disabled; the clock signal is locked by default to the same
clock as the selected input source (i.e. Host Output or AES Input). Summary data is still displayed
confirming the current automatic selection.

The Input Configuration screen is disabled; the input type selected via the Input Toggle (Host Output or
AES Input) is set as Priority 1 for the selected Module and corresponding input (i.e. Module A Input =
Host Out 1 or AES In 1, Module B In = Host Out 2 + AES In 2, etc.)

The Output Configuration screen is disabled; the Module is set to pass the processed signal to the
corresponding Host Input and AES Output (i.e. Module A = Host In 1 + AES Out 1,
Module B= Host In 2 + AES Out 2, etc.)