12 global control tab, Lake-enabled amplifier reference – Lab.gruppen PLM 20K44 User Manual

Page 267

Advertising
background image

262

Lake Controller Operation Manual Rev 1.5.4

Lake-enabled Amplifier Reference

Amplifier Output

Other: Audio distribution

Other: Network

The ALL button restores the default state of all six categories being selected.

20.11.3.3 Time

It is possible to display only events which have occurred within a user-defined time interval, using the
buttons in the TIME box. The options are:

SINCE HH:MM – Tapping the HH and MM buttons opens a numeric keypad to allow a ‘Start time’ for
displayed events to be entered. Tapping the SINCE button activates the option.

LAST POWER CYCLE – Tapping this button causes the Event Log to only display events which have
occurred since the last time the was powered up.

20.12 Global Control Tab

The GLOBAL CONTROL tab is the second of two tabs available in AMPLIFIER GLOBAL VIEW.

To access AMPLIFIER GLOBAL VIEW:

1. Select the ALL page.

2. Tap GLOBAL INFO.

3. Tap EVENTS & CONTROL [F8]

4. Tap the CONTROL tab

Advertising
This manual is related to the following products: