Lake Controller Operation Manual Rev 1.5.4

EQ/Levels Menu Reference

Figure 6-5: AmpClip Level Indicators

6.2.7.6 Level Limits

This function button is visible only in Designer Mode, and is used for setting minimum and maximum values
for all Levels attributes described in this chapter.

6.2.7.7 Adjust Factory

This function button is visible only in Designer Mode and is used for defining default level settings and level
limits for all attributes described in this chapter.

6.3 EQ

The Controller has two types of input EQ: Parametric EQ and Graphic EQ. Additional parametric output EQ
is available on the XOVER page and Aux tabs. This section deals with input EQ.

Groups and Modules can have multiple layers of EQ, called EQ overlays. Each Module can have up to eight
EQ overlays, and each Group can have up to four EQ overlays. A Module can have up to 256 input EQ filters
distributed amongst these EQ overlays. The large number of filters is necessary in order to allow for sophis-
ticated Grouping of Graphic EQ overlays. Input EQ Overlays can be stored and recalled from a file.

A Module’s overall input EQ response is calculated by combining its input EQ overlays with those of all
Groups to which that Module is assigned. The resulting composite EQ curve is indicated by a white line that
is displayed on all overlays.