• For details about UNIX commands and parameters, see UNIX Supplement.

• For details about “syslog” command, see “Remote Maintenance by telnet”.

Message List

183

Message

Problem and solutions

trap account is unavailable.

v3Trap cannot be sent. This could be because

the

Trap destination account is different from theac-
count specified by the printer.

Updated (option name) (value) via DHCPv6

Server

The parameter obtained from the DHCP server
hasbeen updated.

WINS name registration: No response to server
(WINS server address)

There was no response from the WINS server.

Check the correct WINS server address is en-

tered.

Alternatively, check the WINS server is function-
ingproperly.

WINS wrong scopeID =< scopeID >

An invalid scope ID was used. Use a valid scope
ID.

write error occurred.(diskfull)

A “diskfull” error occurred while the printer was-
writing to the spool file. Wait for the current print-
job to finish. When it finishes, more HDD space
willbe available. Only page that were spooled
whenthe error occurred will be printed.

write error occurred.(fatal)

A fatal error occurred while the printer was
writingto the spool file. Turn off the power of
the printer,and then turn it on again. If the error
recurs, contactyour service representative. The
print job that wasbeing spooled when the error
occurred will not beprinted.