Running get_pll.tcl on the quartus ii tcl console, Running get_pll.tcl on the command line or unix – Altera HardCopy II Clock Uncertainty Calculator User Manual

Page 18

Advertising
background image

2–4

Altera

Corporation

HardCopy II Clock Uncertainty Calculator User Guide

Running the Clock Uncertainty Calculator Flow

Running get_pll.tcl on the Quartus II Tcl Console

Figure 2–2

shows the PLL settings summary extraction using the

Quartus II software.

Figure 2–2. Example for Getting PLL Settings on the Quartus II Tcl Console

Running get_pll.tcl on the Command Line or UNIX

Figure 2–3

shows the PLL settings summary extraction using the

command line or UNIX.

Figure 2–3. Example for Acquiring PLL Settings on UNIX Prompt

After you complete the PLL extraction, you will have generated two files,
pll_settings_summary.txt

and PLL_Names.txt, in the working directory.

You should also check the log file to confirm that the PLL extraction job
has completed without any errors.

The pll_settings_summary.txt file contains PLL indices, PLL names,
feedback counter (M) values, charge pump current, loop filter resistances,
voltage controlled oscillator (V

CO

) frequency, and phase frequency

detector frequency, that are required for running the clock uncertainty
calculators. You will need pll_settings_summary.txt to continue the
clock uncertainty calculator spreadsheet.

Advertising