Temperature sense, Temperature sense –41 – Altera Transceiver Signal Integrity Development Kit, Stratix V GT Edition User Manual

Page 49

Advertising
background image

Chapter 2: Board Components

2–41

Power Supply

May 2014

Altera Corporation

Transceiver Signal Integrity Development Kit

Stratix V GT Edition Reference Manual

Temperature Sense

The Stratix V GT die uses a MAX1619 temperature sense device for temperature
monitoring. The device connects to the MAX II CPLD EPM2210 System Controller
and the Stratix V GT device by a 2-wire SMB interface. The MAX1619 device is located
at slave address 0011000b (18h).

The OVERTEMPn and TSENSE_ALERTn signals are driven by the MAX1619 temperature
sense device based on a programmable threshold temperature. The OVERTEMPn signal
is driven to the MAX II System Controller. An over-temperature warning LED (D7)
indicates the temperature fault condition.

Table 2–43

lists the temperature sense interface pin assignments, signal names, and

functions.

Table 2–44

lists the temperature sense component reference and manufacturing

information.

Table 2–43. Temperature Sense Pin Assignments, Schematic Signal Names, and Functions

Board

Reference

(U12)

Schematic Signal

Name

I/O

Standard

MAX II CPLD

System Controller

Pin Number

Stratix V GT

Device

Pin Number

Description

14

SMBCLK_TEMP

3.3-V

D3

B8

SMB clock

12

SMBDATA_TEMP

3.3-V

C2

A8

SMB data

11

ALERTn

3.3-V

D2

E8

Programmable alert

9

OVERTEMPn

3.3-V

E4

E7

Fan enable

3

TEMPDIODE_P

3.3-V

V11

Current source and remote
diode input

4

TEMPDIODE_N

3.3-V

U11

Remote diode input

Table 2–44. Temperature Sense Component Reference and Manufacturing Information

Board Reference

Description

Manufacturer

Manufacturing

Part Number

Manufacturer

Website

U12

Temperature sense, remote and
local, programmable alert.

Maxim

MAX1619MEE+T

www.maxim-ic.com

Advertising