Specification

Dynamic Range

70 dB

Typical Frequency Range

Within +0.5 and -3 dB
between 10 Hz to 25 kHz

Measurement Ranges

A LO 30 - 100 dB(A)
A HI 65 - 135 dB(A)
C LO 30 - 100 dB(C)
C HI 65 - 135 dB(C)

Accuracy

±1 dB

Microphone Type

CEL ¼ inch pre-polarised electret

Time Weightings

F (fast)

125 ms

S (slow)

1 s

I (impulse)

35 ms rise time
1.5 s decay

MAX (hold)

Holds readings of
F, S & I with
<1 dB/5 min

decay.

DC Output from 3.5 mm 3 pole
coaxial socket in bottom of the
instrument case between ring
and ground

Log signal: nominal 25 mV/dB
(offset by approx. 4 to 5 V) and
not exceeding 6 V

AC Output from 3.5 mm 3 pole
coaxial socket in bottom of the
instrument case between pin
and ground

Conditioned signal: 7.25 V RMS
for FSD

Operating Temperature

-10 to +50

o

C

Storage Temperature

-20 to +60

o

C

Sensor Specifications