43

Thermal and Centering

If a bar code is not within the predefined window, it will not be

decoded or output by the imager. If centering is turned on by

scanning Centering On, the imager only reads codes that intersect

the centering window you specify using the Top, Bottom, Left, or

Right bar codes. Scan Centering On, then scan one of the

following bar codes to change the top, bottom, left, or right of the

centering window. Then scan the percent you want to shift the

centering window using digits on the inside back cover of this

manual. Scan Save. Default Centering = 40% for Top and Left,

60% for Bottom and Right.

Centering On

Top of Centering Window


Left of Centering Window

*Centering Off


Bottom of Centering Window


Right of Centering Window