Codabar – Argox AS-9500 User Manual

Page 55

Advertising
background image

54

Codabar

Check Character
Codabar check characters are created using different “modulos.”

You can program the imager to read only Codabar bar codes with

Modulo 16 check characters. No Check Character indicates that

the imager reads and transmits bar code data with or without a

check character. When Check Character is set to Validate and

Transmit, the imager will only read Codabar bar codes printed

with a check character, and will transmit this character at the end

of the scanned data. When Check Character is set to Validate, but
Don’t Transmit
, the unit will only read Codabar bar codes printed

with a check character, but will not transmit the check character

with the scanned data.

<Default All Codabar Settings>

*On

Off

Start /Stop Character

Transmit

*

Don’t Transmit

Check Character

*No Check Character

Validate and Transmit

Validate Modulo 16 and
Transmit

Validate Modulo 16 ,but Don

’t

Transmit

Advertising