47

Output Sequence

Output Sequence Example

In this example, you are scanning Code 93, Code 128, and Code

39 bar codes, but you want the imager to output Code 39 1st, Code

128 2nd, and Code 93 3rd, as shown below.

Note: Code 93 must be enabled to use this example.

You would set up the sequence editor with the following command

line:

SEQBLK62999941FF6A999942FF69999943FF

The breakdown of the command line is shown below:

SEQBLKsequence editor start command 62 code identifier for

Code 39 9999 code length that must match for Code 39, 9999 = all

lengths 41 start character match for Code 39,
41h = “A” FF termination string for first code

6A code identifier for Code 128 9999 code length that must match

for Code 128,

9999 = all lengths 42 start character match for Code 128,
42h = “B” FF termination string for second code

69 code identifier for Code 93

9999 code length that must match for Code 93,

9999 = all lengths 43 start character match for Code 93,

Advertising