Figure 1-6. style number identification chart -8, Figure 1-6. style number identification chart, Be1-25 – Basler Electric BE1-25 User Manual

Page 18

Advertising
background image

Figure 1-6. Style Number Identification Chart

OPTION 3

OPTION 4

OPTION 2

OPTION 1

SUPPLY

RANGE

SENSING INPUT

M

POWER

BE1-25

MODEL NO.

SENSING INPUT

TYPE

M) Single Phase

Voltage

OUTPUT

TIMING

TARGET

N) None

A) One Internally

Operated

B) One Current

Operated

F) Semi-Flush

Mounting

P) Projection

Mounting

1) 120 Vac, 1-99°

Phase Angle

Setting

9) 120 Vac, 1-99°

Phase Angle

Setting With

Expandable

Window

1

E) Sync-Check

NO Relay

F) Sync-Check

NO Relay with

Push-to-

Energize

Output

G) Sync-Check

NO Relay and

Voltage Monitor

SPDT Relay

H) Sync-Check

NO Relay and

Voltage Monitor

SPDT Relay

with Push-to-

Energize

Output (for

both relays)

4

4

A6) 0.1-99 Sec.

A7) 1-99 Cycles

O) 48 Vdc

P) 125 Vdc or

100/120

Vac

R) 24 Vdc

T) 250 Vdc or

240 Vac

3

4) Non-Isolated

Contact

Sensing

Input

5) Isolated

Contact

Sensing

Input

N) None

R) Line and Bus

Voltage Monitor

and Voltage

Difference with

PC Bd Mounted

Switches

S) Line and Bus

Voltage Monitor

with PC Bd

Mounted Switches

T) Voltage Difference

Voltage Monitor

and Voltage

Difference with

External Contact

Inputs

V) Line and Bus

Voltage Monitor

with External

Contact Inputs

0) None

1) Sync-Check

Auxiliary Output

NO Relay

2) Sync-Check

Auxiliary Output

NC Relay

3) Sync-Check

Auxiliary Output

SPDT Relay

6) Power Supply

Status Output

1

CONTACT SENSING MODULES

(Required when Type T Power Supply is specified)

Module Ordering Number

9 1702 06 106

Non-Isolated

Contact Sensing

Isolated

Contact Sensing

Number of

Contacts

Sensed

Relay Options

Voltage Monitor

with External

Contact Inputs

plus Expandable

Phase Window
Voltage Monitor

with External

Contact Inputs
Expandable Phase

Window
None of the above

9 1702 06 100

9 1702 06 101

9 1702 06 107

9 1702 06 104

9 1702 06 110

9 1702 06 105

9 1702 06 111

6

5

2

1

NOTES:

When Sensing Input Range 9 is Selected from the
Style Chart, Option 3 must be 0.
All relays are supplied in an S1 size case.

Requires Contact Sensing Module. See Table in this chart.

Not available if Option 2 is B, N, or T.

1

3

4

2.

D434-006.vsd

01-30-01

A) Average

Voltage Monitor

and Voltage

Difference with

PC Bd Mounted

Switches

U) Line and Bus

C) Average

B) Average Voltage

Difference

Voltage Monitor

and Voltage

Difference with

External Contact

Inputs

For more information on contact sensing see Specifications.

5

5

1-8

BE1-25 General Information

9170200990 Rev U