Schedule name, Time zone profile, First occurrence – Comtech EF Data Vipersat Circuit Scheduler v3.7.x ArrangeLink User Manual

Page 51: Exclusion profile, Max. execution delay, Schedule tag

Advertising
background image

Chapter

3 -

Using ArrangeLink

3-9

Schedule Setup

Schedule Name

Enter a name for the event that is being scheduled in the Schedule Name box.

The name entered is used to identify this event. This field entry defaults to a

name consisting of the current date and time.

Time Zone Profile

The time reference for this event can be specified from the pull-down menu as

one of the following:

1 Pacific Time
2 Eastern Time
3 Greenwich Time

First Occurrence

Select either Yes or No from the pull-down menu, depending on whether or not

this is a first occurrence for a recurring event.

Exclusion Profile

Although this feature appears as a settable option, it is not supported in v3.7.2 of

the VMS.

Max. Execution Delay

The time interval specified for the Maximum Execution Delay parameter

ensures that an event will still be executed, even if a delay should occur beyond

the scheduled start time—caused by the VMS being temporarily unavailable,

for example. However, if the delay exceeds this interval, the event will not be

executed.
The default value for this parameter is 600 seconds (10 minutes). This entry

should be set to an interval that is less than the specified duration of the event.
When the scheduled start time for the event occurs, the VMS will attempt to set

up the defined circuit and will continue to do so for the delay time interval until

either a connection is made or the event’s time allocation is exceeded

Schedule Tag

In addition to the Schedule Name, one or more Schedule Tags can be associ-

ated with an event, or a group of common events. This provides another means

for filtering events with the search function when viewing scheduled events (see

the section “Schedules” on page 3-28).
Enter any desired combination of characters to insert a Tag for the event.

Advertising