13.7 4000XA, 4180, 4280 - Cabling to an AT&T SAC E2A Remote


The 4000XA, 4180 and 4280 are able to accept the E2A protocol on any of its ports. The
AT&T SAC is an E2A remote interface for discrete scan points.

The AT&T SAC presents a DB25 Male connector. A special adapter depicted below
must be used to interface to the AT&T SAC. In addition, the port is configured as
prot=E2A, DXE=DTE, and PAP=ON. The originate and receive options for the port are
dependent on the deployment.

1 2 3 4 5 6 7 8

RJ45 Female Pin Numbering

RJ45

1

2

3

4

5

6

7

8

4180 & 4280 to SAC Adapter

DB25

1

2

3

4

5

6

7

8

Female

DCD

SG

DSR

CTS

RTS

RxD

TxD