13.8 9480, 4284 - Cabling to an AT&T SAC E2A Remote


The 4284 and 9480 are able to accept the E2A protocol on any of its ports. The AT&T
SAC is an E2A remote interface for discrete scan points.

These instructions for the interface to the AT&T SAC E2A Remote substantially differs
from the 4000, 4180, and the 4280. Specifically, a special interface adapter is no longer
required.

The AT&T SAC presents a DB25 Male connector. The adapter used to connect to the
AT&T SAC is the standard asynchronous DCE with a DB25 female.

When a 9480 is used, it is connected directly to the AT&T SAC E2A remote without
special cabling.

The configuration of the port is as follows:
Port <port num> type=orig prot=e2a
Port <port num> dest=<

E2AHOB

IP Address> dport=<

E2AHOB

TCP Port>

Port <port num> dxe=dce swcar=on
Rs <port num>

In the example above, the

E2AHOB

may be replaced with an

IP-E2A

application

instance on a 6xxx. Please note that the E2A protocol functionality of this release of the
xxxx requires release 5.1 of IP-E2A or later.