Foxconn Q67M-S User Manual

Page 103

Advertising
background image

5

9�

4. A "

DeGRADeD VolUMe DeTeCTeD" screen pops out asking you to select a new

hard disk for rebuilding. Here, we select ST 74.5GB. Press <Enter> to select it.

5. It goes back to Main menu with a "Rebuild" status of RAID5 volume. Eventually,

a replacement hard disk has to join in and it always keeps three hard disks in the
RAID5 system.

�. Operating System will perform the re�uilding later.

Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5

Copyright(C) 2003-04 Intel Corporation All Rights Reserved.

1. Create RAID Volume

2. Delete RAID Volume

4. Recover Volume Options

5. Exit

RAID Volume :

ID

Name

Level Stripe

Size Status Boota�le

0

TryRAID5

RAID5(Parity)

64KB 149.1GB

0

TryRAID5

RAID5(Parity) 64KB 149.1GB

Re�uild

Yes

Physical Disks:

Port Drive Model

Serial #

Size Type/Status(Vol ID)

0

Hitachi HDS72161

PVF904�21G2J�M

149.0GB

Hitachi HDS72161

PVF904�21G2J�M

149.0GB

PVF904�21G2J�M

149.0GB

Member Disk(0)

1

ST380811AS

5PS1TAGW

74.5GB

Member Disk(0)

2

SAMSUNG HD1�1HJ S0V3J9APA30524

149.0GB

S0V3J9APA30524

149.0GB

149.0GB

Non-RAID Disk

3

ST380815AS

5RW1CA37

74.5GB

Member Disk(0)

Volume with “Re�ulid” status will �e re�uilt within the operating system.

Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1032

Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.

[

DISK/VOLUME INFORMATION

]

[

MAIN MENU

]

3. Reset Disks to Non-RAID

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5

Copyright(C) 2003-04 Intel Corporation All Rights Reserved.

1. Create RAID Volume

4. Recover Volume Options

2. Delete RAID Volume

5. Acceleration Options

3. Reset Disks to Non-RAID

�. Exit

RAID Volume :

ID

Name

Level Stripe

Size Status Boota�le

0

TryRAID5

RAID5(Parity)

64KB 149.1GB

0

TryRAID5

RAID5(Parity) 64KB 149.1GB

Normal

Yes

Physical Disks:

Port Drive Model

Serial #

Size Type/Status(Vol ID)

0

Hitachi HDS72161

PVF904�21G2J�M

149.0GB

Hitachi HDS72161

PVF904�21G2J�M

149.0GB

PVF904�21G2J�M

149.0GB

Member Disk(0)

1

ST380811AS

5PS1TAGW

74.5GB

Member Disk(0)

2

SAMSUNG HD1�1HJ S0V3J9APA30524

149.0GB

S0V3J9APA30524

149.0GB

149.0GB

Non-RAID Disk

3

ST380815AS

5RW1CA37

74.5GB

Non-RAID Disk

Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1032

Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.

[

DISK/VOLUME INFORMATION

]

[

MAIN MENU

]

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

"Degraded" volume and disk available for rebuilding detected. Selecting

a disk initiates a re�uild. re�uild completes in the operating system.

Select the port of the destination disk for re�uilding (ESC to exit):

Port Drive Model

Serial #

Size

2 SAMSUNG HD161HJ

S0V3J9APA30524

140.9GB

3 ST380815AS

5RW1CA37

74.5GB

[

DEGRADED VOLUME DETECTED

]

3

ST380815AS

5RW1CA37

74.5GB

3 ST380815AS

5RW1CA37

74.5GB

[↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit

Advertising