Installation

Installation of Electrical Supply
The

RP620* is supplied with an external electrical control box pre-

wired by the factory. The control box is connected to the fireplace

with a 30 foot long 6-conductor cable that will communicate with

the fireplace. Extension cables are available through your Montigo

Dealer only.
A 20ft low voltage black / white cable is provided for connection

to a single pole on/off switch. The length of this cable can be

extended up to a length of 100ft using a cable of equal or greater

capacity. This system operates on 24VAC. Do not connect this

switch circuit to an external power source.
Optional remote control available through your Montigo Dealer.
Do not use third party remote controls without the approval from

Montigo.

Section 4: Wiring

Installing the Fireplace Control Box
Install the Fireplace Control Box in an accessible location. The

location should be where maintenance, adjustments and service

may be made easily.

Conduit & Wiring clearances

Connect the power vent harness as outlined in the previous section.

Ensure that the proper clearances are maintained for the wiring and

conduit. When installing the wiring it must never run above the vent

run and it must be at least 1" clear of all venting.

1” Clearance

Wire

Note: If any of the original wire supplied with the appliance is

replaced, it must be with the same or it's equivalent.

Installations in Canada must be electrically grounded in

accordance with

CSA C22.1 Canadian Electrical Code Part 1

and/or Local Codes.
Installations in the USA must be electrically grounded in

accordance with local codes or, in the absence of local codes,

with the National Electrical Code,

ANSI/NFPA 70.

Figure 11. Control Box

Left-side View

Right-side View

Power Vent

Harness

Power Vent

Speed Control

Post Purge

Timer (3 min.)

Prepurge

Timer (1 min.)

Power

Vent Fuse

(5A)

Power Vent

Connector

Control

Panel Fuse

(5A)

LED

Power

Indicator

Heat Sensor /

Conmustion Switch

Figure 12. Conduit and Wiring

LED Indicator

Fuse

115V

Power Supply

Wall Switch Control

cable

115V

Outlet

Figure 10. Control box Diagram