RP620 Power Vent Indoor Gas Fireplace

Page 27

XG0777 - 122014.1

Installation

Section 7: Venting Configuration for PVHIN58-300 with TMHIN58-40

Minimum 7' of pipe

between fireplace and

power vent

Vent configurations can include vertical sections, horizontal sections, elbows, flex and/or rigid vent

sections. The maximum length of any vent run is 80'. Follow the rules outlined below to determine your

specific vent options. All venting is to be 5" inner and 8" outer sizing. Because this appliance intended to

only be installed with a power vent termination, vertical and horizontal runs can be calculated in the same

manor.
Flexible venting does not flow quite as well as rigid pipe, so a factor needs to be applied, making the total

allowable vent run shorter than rigid pipe.

* Not for rigid elbows used in between flex sections

Venting Calculation

Rigid Vent

Flex Venting

Maximum Vent Run - Rigid

50' total length

40' total length

90 degree elbow

subtract 10' each

* subtract 5' each

45 degree elbows

subtract 5' each

* subtract 2' each

Down sections

subtract 2' for every 1' down

subtract 2' for every 1' down

Flex Venting (if mixed with rigid)

Subtract 1.3' for every 1'

section

Figure 19. Venting Configuration

Vent configurations can include vertical sections, horizontal sections, elbows, flex and/or rigid vent sections. The maximum length of any vent

run is 50'. Follow the rules outlined below to determine your specific vent options. All venting is to be 5" inner and 8" outer sizing. Because

this appliance is intended to only be installed with a power vent termination, vertical and horizontal runs can be calculated in the same manor.
Flexible venting does not flow quite as well as rigid pipe, so a factor needs to be applied, making the total allowable vent run shorter than

rigid pipe.