Lp conversion, Warning, Installation – Montigo 30FID Traditional User Manual

Page 18

Advertising
background image

Page 18

XG00516-

150204

I-Series Indoor Gas Fireplace

Installation

LP Conversion

The 30FID-S is available in Natural Gas or Liquid Propane versions.

Should you have a Natural Gas unit that you would like to burn

Propane with; you can purchase an optional LP conversion kit

and install it using the following steps. To convert the unit to LP,

the unit must be disconnected from any gas supply, disconnected

from any electrical supply and batteries and removed from any

installation cavity.

Figure 1 Sec.6 LP conversion kit showing pilot orifice, main burner

orifice, LP stepper motor, zap strap and gas fitter conversion label.

Tools required
1). Torx T20 Screw Driver Bit
2). 3/8" Socket Driver
3). 5/32" Allen Key
4). Needle Nose Pliers or Small Flat Head Screw Driver

The 6 major items that need modification to convert a unit to LP
1). Variable regulator on the gas valve
2). The main burner orifice
3). The pilot burner orifice
4). Set minimum primary air tab
5). Label on the valve showing the new specifications
6). Gas fitter conversion label

Figure 5 Sec. 5 Location of Door retainer tabs

Check that the door retainers are properly engaged. If they are

not the door relief system may not operate properly. This can

cause a risk of injury or improper operation of the appliance.

WARNING

When installing the fireplace - gas lines, fittings,

accessories or any other objects cannot impede the

proper movement of the door buckles.