Installation – Montigo 30FID Traditional User Manual

Page 19

Advertising
background image

Page 19

XG00516-

150204

I-Series Indoor Gas Fireplace

Installation

Converting the gas regulator on the valve

1). On the right side (control side) of the unit, remove 2 screws

that enable the valve to swing away from the unit.

2). Swing the valve away from the unit in order to get access to

the front of the valve and regulator. Be careful not to damage gas

lines or wires.

3). Using a T20 Torx screw driver, remove the 2 screws that attach

the stepper motor to the valve.

4). Remove the screws, stepper motor and rubber diaphragm.

5). Remove the top 2 screws that hold the control mounting

bracket in place.

Figure 2 Sec.6

Figure 3 Sec.6

Figure 4 Sec.6

Figure 5 Sec.6

Figure 6 Sec.6