Maintenance – Montigo 30FID Traditional User Manual

Page 61

Advertising
background image

Page 61

XG00516-

150204

I-Series Indoor Gas Fireplace

Maintenance

Figure 59 Sec.10

7). Disconnect both the Ignition Lead and the Flame Sensor Lead
from the front of the Control Panel

8). Feed the 2 electrical lines from the Control Board to beside the unit.

Figure 60 Sec.10

9). From the inside of the Firebox, pull the Pilot Assembly, Bulk Head
Plate, Gasket and 3 lines through the Firebox and out of the unit.
Leave ground wire in the firebox.

Figure 61 Sec.10

10). Install the replacement Components in the reverse order, through
the Firebox wall. Install the Pilot Assembly Bracket to the Firebox
floor with 2 screws. Pass the wires through rubber gasket. Make
sure the pilot gas line goes through the far right hole of the gasket
and the cuts in the gasket face up. Make sure that the Ground Wire,
Star Washer and screw are assembled to the bottom of the Pilot
Mounting Bracket as shown in the picture below.

Figure 62 Sec.10

11). Using a round object, something like a Socket Wrench, loop
the excess Pilot Line into a coil. Be very careful not to kink the line.

Figure 63 Sec.10

Figure 64 Sec.10

Advertising
This manual is related to the following products: