Maintenance

Accent Light Replacement

Replacement of the fireplace accent lights can be performed with
a few simple steps. The accent lights are located at the top of
the fireplace near the front on either side. Although they can be
changed without removing any components, it would be easier to
remove the Fireplace Panels and Upper Retaining Clip.

We recommend that if you have a need to replace one bulb, you
replace them all at the same time. Another option would be to
replace them at the same time as your annual service.

1). Disconnect the electrical and gas supply to the unit.
2). Remove door and safety screen barrier from the unit.

3). See the section on Fireplace Panel Installation for information
on how to remove the Panels. Once they have been removed, the
Upper Panel Retainers can be removed.

Figure 32 Sec.10

Figure 33 Sec.10

4). To remove a bulb, pull it out of it's socket. New bulbs can be bought
at most national hardware stores or through your Montigo fireplace
dealer. See specs page for information on bulbs. If you supply your
won bulbs, do not use greater than 20 watt bulbs.

5). Replace the Upper Panel Retainers and Firebox Liners.

Optional Fan / Blower Replacement

The Optional Fans or Blowers supplied with your fan kit are the
best quality available. These Fans should provide years and years
of trouble free service. There are 2 blowers for this appliance, one
which has the motor on the right side and the other on the left side.

** If the fireplace is installed, the Gas Supply may need to be
disconnected from the Appliance. If this is the case, a license gas
fitter will need to provide this service.

**

Figure 34 Sec.10

1). If installed, disconnect Electrical Power. Always disconnect

the power when servicing any appliance.

2). Remove Front and Rear Faceplate. See the section on
Faceplate installation for details.

3). Remove the Flue Collar Slide Plate. See the section on Vent
Connection for details.

4). Remove the Fireplace from the cavity.

5). Remove all screws necessary to remove the Outer Shell Back.