Introduction, Installation introduction – Montigo 30FID Traditional User Manual

Page 4

Advertising
background image

Page 4

XG00516-

150204

I-Series Indoor Gas Fireplace

Installation

Introduction

Congratulations on your purchase of a

Montigo Fireplace.

With over 30 years of experience, Montigo is committed to providing

you with a gas fireplace that is not only a beautiful addition to your

space, but that is also designed and manufactured to the highest

safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions

laid out in this Installation, Operation and Maintenance Manual

and retain it for your future reference. Pay special attention to all

cautions, warnings, and notices throughout this manual intended

to ensure your safety.
This manual covers installation, operation and maintenance. Lighting,

operation and care of this fireplace can be easily performed by the

homeowner. All installation and service work should be performed

by a qualified or licensed installer, plumber or gas fitter as certified

by the state, province, region or governing body where the fireplace

is being installed.
This installation, operation and maintenance manual is applicable

to the models described below. Refer to your rating plate to verify

included options.

Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any

responsibility for, the following actions:

► Modification of the fireplace and/or components including

Direct-Vent assembly or glass doors.

► Use of any component part not manufactured or approved

by Montigo in combination with this Montigo fireplace system.

► Installation other than as instructed in this manual.

Consult your local Gas Inspection Branch on installation requirements

for factory-built gas fireplaces. Installation & repairs should be done

by a qualified contractor.

This appliance is equipped for altitudes from 0 - 4500 feet [0

-1370 m]. For higher altitudes contact your Montigo dealer.

30FIDN-S-F [NG]

30FIDL-S-F [LP]

Input Rating

24,000 BTU

23,000 BTU

Gas Supply Pressure

7" WC

11" WC

Manifold Pressure
High

3.5"

10"

Low

2.2"

6.4"

Orifice Size (DMS)

41

54

Pilot Orifice Size (No.)

62

35

Air Shutter Min Settings

1/16"

3/16"

Electrical Requirement

115 VAC, 60Hz

115 VAC, 60Hz

Vent Size

3"

3"

Aluminum / Stainless Flex

Minimum Vent Length

10'

10'

Maximum Vent Length

36'

36'

Efficiency AFUE Method

71.30%

71.30%

Efficiency P.4 Method

78.8%

80.1%

Clearances
Mantel

16"

16"

Hearth

0"

0"

Side Wall

7 7/8"

7 7/8"

Control Type

SIT Proflame 2

SIT Proflame 2

Light Bulb Specification 20W, G6.35, Qty 2

20W, G6.35, Qty 2

Fuse Specification

3.15Amps

3.15Amps

Fan Amperage

1.6Amps

1.6Amps

Certification(s)

Ansi Z21.88-2014 / CSA 2.33-2014 VENTED GAS FIREPLACE HEATERS
CGA 2.17-M91 [R2009] GAS FIRED APPLIANCES FOR HIGH ALTITUDES
CSA P.4.1-09 [R2014] Fireplace Efficiency