Gas line connection, Warning, Installation – Montigo 30FID Traditional User Manual

Page 23

Advertising
background image

Page 23

XG00516-

150204

I-Series Indoor Gas Fireplace

Installation

Gas line connection

The 30FID-S Insert is supplied with a flexible gas line that uses

a ½” female flair to connect to your service. The flexible gas

line is a one time connection. If you ever have to break the

connection, you must replace the flexible gas line. There is

also a safety shutoff valve that is built in and operated when

needed used the door removal tool. Depending on your local

gas codes, you may need to provide an additional gas shut

off valve or even hard pipe the unit. In the event that you

need to hard pipe the gas supply, a union will be required.

Emergency Shut-off Valve

This appliance is equipped with a shut-off valve for use incase

of emergency. It is located on top of the appliance gas valve

and can be accessed and operated through the front of the

fireplace using the door tool. Appliance is shipped from the

manufacturer with the emergency shut-off valve in the closed

position.

Hook the door tool into the arm of the emergency shut-off valve.

Pull the door tool towards you to open the valve and push it away

from you to close the valve.

Hook Door Tool Here

Pull This Direction

To Open

WARNING

When installing the fireplace - gas lines, fittings,

accessories or any other objects cannot impede the

proper movement of the door buckles.

Figure 24 Sec.6

Figure 25 Sec.6 Inserting door tool through the front of the fireplace

Figure 26 Sec.6 Emergency shut-off valve shown in closed position