52

Save SG Config

Allows you to save an SG configuration preset that can then be selected using the SG Config:
setting at the top of the Stereo Generator menu.

Delete SG Config

Allows you to delete a previously saved SG configuration preset.

Rename SG Config

Allows you to rename a previously saved SG configuration preset.

<- Exit

Click on this option to return to the Main menu.


Discrete I/O

<- Exit

Click on this option to return to the Main menu.

Mtr Select

Selects what signal feeds the LED front panel meters. You can select Input, Analog Out, AES Out or LW
(Livewire) Out
.

Input

<-Exit

Click on this option to return to the Discrete I/O submenu.

Input Src (Input Source)


Selects the primary input source to be used. You can select Analog, AES/EBU or LiveWire.

Failover Opts (Failover Options)


[Fover Time] (Failover Time)

When set to a value other than zero (disabled) allows the Omnia.ONE to automatically
select another input source if the currently selected one fails. Failover Time is the amount
of time that will elapse after the failure of audio on the primary input source before the
unit makes the decision to switch to the secondary (failover) input source. For instance, if
Failover Time is set for 5 seconds and the primary audio source fails, 5 seconds later the
unit will switch to the secondary audio input if that input is active. If, at any time, audio
is restored on the primary input (for 1 second, continuously), the unit will switch back to
the primary audio input. It will remain with the primary input unless another failure is
detected.