Troubleshooting

System Manager TS II LEDs, Buttons,

Dipswitches & Jumpers

LEDs and system function buttons are located behind your System
Manager TS II’s cover. See Figure 137 for locations. Dipswitches and
jumpers are located on the back of your System Manager TS.

Power LED

This LED will light up and stay on as long as power is supplied to
your TS.

Operation LED

This LED will blink once a second to indicate that the system is alive.

Update LED

This LED will turn on when the Update program is running.

Screen Refresh LED

This LED will turn on when the screen refreshes.

Communications LED

This LED will light up and blink when there is a connection with the
CommLink and/or network. If you are using your TS in stand-alone
mode, this LED will not light up.

Reset Button

Press this button to reset the screen. The screen should refresh itself to
the Main Screen within 2 minutes.

Diagnostics Button

Under the direction of WattMaster Controls Technical Support, you
may have to perform diagnostics on your System Manager TS II. Press
this button to do so.

Touch Screen Suspend Button

Press this button to temporarily freeze the touch screen function of your
System Manager TS II in order to clean the screen. Always use a dry,
dust -free cloth to clean the screen.

OPT1 Dipswitch

For High Speed applications, the OPT1 Dipswitch should be ON. For
all other applications, it should be OFF. This Dipswitch is located on
the back of the System Manager TS. See Figures 5-8, pages 8-11 for
location.

OPT4 Dipswitch

As of April 2014, Dipswitch OPT4 should be set to ON by default.
Previous versions should be set to OFF. If you see your screen is not
centered correctly, switch OPT4 to the opposite position. This Dipswitch
is located on the back of the System Manager TS. See Figures 5-8,
pages 8-11 for location.

TERM Jumpers

Both TERM Jumpers must be ON for Stand-Alone applications
(No CommLink or MiniLink). Both TERM Jumpers must be OFF for
applications with CommLink(s) and/or MiniLink(s). See Figures 5-8,
pages 8-11 for location.

Reset Button

A302-12

Power LED

Communications LED

Diagnostics Button

Suspend Button

Not Used
Not Used

Screen Refresh LED

Operation LED
Update LED

Figure 137: System Manager TS II LEDs and Buttons