SMTS II Technical Guide

Components and Wiring

9

SMTS II to VCM-X Controller Wiring

Figure 6: System Manager TS II to VCM-X Controller Wiring

.1uF

YS102178 R4

WQVGA Graphical Interface

WattMaster Controls, Inc

C24

R9

R7

R6

R5

R2

R1

C51

C39

C20

C19

C15

C14

C13

C12

C11

C10

C9

C7

C1

X3

8.00

Mhz

OFF

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1

u

F

.1

u

F

.1uF

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1uF

.1

u

F

.1

u

F

.1

u

F

.1

u

F

1002

.1uF

1002

1002

.1uF

.1uF

.1uF

.1uF

LTC3824

1002

1002

1002

1002

1002

1002

66.000Mhz

MADE IN USA

330uF 50V

330uF

1002

SERIAL #

OP

T

4

OP

T

3

OP

T

2

OP

T

1

TERM

RTC

YS102178 R4

WQVGA Graphical Interface

WattMaster Controls, Inc

CAL

5V

3.3V

2.5V

J3

R34

R

16

R13

R8

R39

X2

R26

R17

R14

C24

U13

R49

R48

R47

R46

R45

R44

R43

R40

R37

R35

R32

R31

R29

R27

R24

R22

R12

R11

R10

R9

R7

R6

R5

R2

R1

L5

L4

D12

D11

D1

C51

C50

C45

C41

C39

C36

C20

C19

C18

C17

C16

C15

C14

C13

C12

C11

C10

C9

C8

C7

C6

C5

C4

C1

J1

R41

C23

C25

C26

R42

X3

R20

C27

C34

C40

U10

U11

C28

C29

R18

C35

D2

L1

R25

C31

R19

U9

R28

C32

R

30

R33

C30

R15

Q2

R21

R23

SW1

C2

C3

V1

R36

1002

R

R

S

S

T

T

T

S

R

+

+

1002

R

T

5V

GND

System Manager TS
Back View

BLACK (R)

BLACK (R)

BLACK (R)

RED (24 VAC)

RED (24 VAC)

To (24 VAC)
Transformer +

T

o

R

T

erminal

On VCM-X

T

o

S

T

erminal

On VCM-X

T

o

T

T

erminal

On VCM-X

To (24 VAC)
Transformer -

BROWN (GND)

Line Voltage

24 VAC Transformer

5 VA Minimum

BROWN (GND)

WHITE (T)

WHITE (T)

WHITE (T)

BARE (S)

BARE (S)

BARE (S)

Run 2 Conductor
Twisted Pair W/Shield
Cable. WattMaster
WR-LL-WG-18 Cable
Or Equivalent From
System Manager To
VCM-X Controller

Run 2 Conductor 20 Ga. Minimum Cable From
System Manager TS Terminals To 24 VAC

TERM

NOTE: For Stand-Alone
Installations (No CommLink
or MiniLink), Both TERM
Jumpers Must Be ON.
For All Applications With
CommLink(s) Or MiniLink(s),
Both Jumpers Must Be OFF.

OFF

OP

T

4

OP

T

3

OP

T

2

OP

T

1

NOTE: Dip Switches OPT1,
OPT2 & OPT3

.

Should Be

Set To Off As Of April 2014,
OPT4 Should Be Set To ON
By Default. Previous Versions
Should Be Set To OFF. If You
See Your Screen Is Not
Centered Correctly, Switch
OPT4 To The Opposite
Position.

VCM-X Controller - Front View

AI1

AI1 SET

AI2 SET

AI3 SET

AI4 SET

AI5 SET

AI7 SET

AI2

AI3

AI4

AI5

AI7