REMKO HEAT PUMP MANAGER

Heating circuit 1/2

Designation

Description

T-supply

Current supply temperature [sensors 05/08] and supply target temperature following pressing of the
respective function key.

Heating circuit enable Heating circuit in heating mode (on/off).

Heating circuit pump Heating circuit pump status (on/off).

B-warm up-time

Last required warm up-time with active warm up optimisation.

Solar / MF

Designation

Description

MF 1

Status of the relay MF 1 (on/off) outlet A8 - 2nd heating appliance.

MF 2

Status of the relay MF 2 (on/off) outlet A9 - charge pump indoor unit.

T-MF 3

Current temperature of the MF 3 sensor [sensor 13] - not used by REMKO.

MF 3

Status of the relay MF 3 (on/off) outlet A10 - 3-way switch valve cooling / MP cooling

MF 4

Status of the relay MF 4 (on/off) outlet A12 - solar-circulation pump.

T-solar 1

Current collector temperature [sensor 14].

T-WW

Current hot water temperature and hot water target temperature [sensor 6].

T-WW U

Current temperature of the buffer tank bottom [sensor 12] (sensor collector system).

Solar pump 1

Status of the collector pump (on/off).

Load Sp WW

Status of the tank charge pump 1 (on/off) not used by REMKO.

Level 4 - DISPLAY - Description of parameters and settings - continued

14