REMKO Multi-talent User Manual

Page 51

Advertising
background image

0000

F17

V

A

B

AB

M

M

F9

1)

2)

4)

M

2)

l/h

Tmax

F8

F6

F11

F5

Designation

Value range

Programming

Output/level

00 – 9950 kW

WE 1 level 1 = 50

WE 2 level 1 = 1
WE 3 level 1 = 1

continue with key next to "End"
MF 1 function

0 0 - 3 6

0 0

T - MF 1 target

- 2 0 °C - 9 0 °C

( ---- )

MF 1 Hyst

2 K - 1 0 K

( ---- )

MF 1 Hyst Off

2 K - 1 0 K

( ---- )

MF 2 function

0 0 - 3 6

18

T - MF 2 target

- 2 0 °C - 9 0 °C

( ---- )

MF 2 Hyst

2 K - 1 0 K

( ---- )

MF 2 Hyst Off

2 K - 1 0 K

( ---- )

MF 3 function

0 0 - 3 6

1 0

T - MF 3 target

- 2 0 °C - 9 0 °C

( ---- )

MF 3 Hyst

2 K - 1 0 K

( ---- )

MF 3 Hyst Off

2 K - 1 0 K

( ---- )

MF 4 function

0 0 - 3 6

0 2

T - MF 4 target

- 2 0 °C - 9 0 °C

( ---- )

MF 4 Hyst

2 K - 1 0 K

( ---- )

MF 4 Hyst Off

2 K - 1 0 K

( ---- )

F15 function

0 0 - 0 8

0 7

E 1 function

0 0 - 0 3

0 2

E 2 function

0 0 - 0 3

0 3

Sensor

1k/5k sensors

5k sensors

Designation

Value range

Programming

BUS code BM

Off, 00-15

Off

Language

D/GB/F/NL/E/I

D (German)

Terminal address

On/Off

On

Time

0-24

Set time

Date

Year, month, day

Set date

BUS code 1

00-15

01

BUS code 2

00-15

02

System selection

---/01-12

03

Regulator type

00-06

06

WE 1 type

00-09

07

WE bus

00-05

05

Gradient

On/Off

Off

WE 2 type

00-22

01

WE 2 tank

00-03

00

WE 3 type

00-09

01

WE 4 type

00-09

00

Buffer type

00-02

00

Cooling mode

Off/On

Off

HC1 function

Standard, T-feed

const, swimming

pool, WW,

return

Standard

HC2 function

see HC1

Standard

Hydraulic diagram for the heat pump assembly 2 (only for CMF 80/140)

Functions: Heating and hot water,

bi-fuel operating mode with boiler

“System selection 3”

Outdoor unit

Indoor unit

CMF 80/140

Process water

Storage tank

HPS 500

Heating/cooling

water

Storage tank

KPS 300

Heating circuit 1 Heating circuit 2

Notes:

1) Recommended location for heat meters. These are not included in REMKO's scope of delivery.

We recommend a set-up with a flow volume of 2.5 m

3

/h.

2) Heating circuit circulation pump(s) not included in REMKO's scope of delivery. We recommend the use of high-efficiency circulation pumps.

4) If the surface heating is the only heat distribution system, it automatically becomes a heating circuit 1. A mixer is not necessary in this case!

Taps

CW inlet

Fresh water station

Gas/oil boiler

Sample hydraulic diagram for system selection 3

51