REMKO HEAT PUMP MANAGER

Various values are summarised here in order toe enable quick access for customer service.
The input of the code number is necessary for some functions.
The relay test and sensor test are automatically reset after 1 minute!

Sensor test no.
Sensor no.

REMKO
Sensor desig-
nation

Description

01

Bottom storage tank sensor

02

FBR-2

Room temperature Heating circuit 1, use for analogue remote control FBR-2

03

FBR-2

Buffer tank temperature top.
Analogue remote control FBR-2

04

not used

05

F5

Supply temperature heating circuit 2 (mixer circuit)

06

F6

Hot water temperature top (process water tank)

07

not used

08

F8

Collector temperature (collective supply temperature sensor)

09

F9

Outdoor temperature

10

not used

11

F11

For CMF 80/90/140/150 and CMT 100/150:

Supply temperature heating circuit 1 (direct heating circuit) or

for EMF/EMT 100, CMF/CMT 120, EMF/EMT 150 and CMF/CMT 160:

Supply temperature heat pump

12

F12

Hot water temperature bottom (reference sensor for solar regulation)

13

F13

not used

14

F14

Solar system collector temperature or solid-fuel-boiler
(Attention: Control characteristic Pt 1000)

15

F15

Status of the switch input signal: Power supply plant enable/disable

16

not used

17

F17

Return temperature sensor

Level 4 - SERVICE - Description of parameters and settings