System selection – REMKO Multi-talent User Manual

Page 47

Advertising
background image

System selection

12 basic hydraulic configurations

are provided in the heat pump

manager which can be pulled up

with the system selection and ap-

plied in the controller.

Pulled up with the system selection

and applied in the controller.

The system selection was decided in
accordance with the following criteria:

1. by type of heat pump

- only heating series:

CMF 80, CMF 140

- Heating/cooling series:
CMF 90/150/120/160,

CMT 100/150/120/160
CMF 120/160
EMT/EMF100/150

System

selection

Functions

1

Basic hydraulics for the functions “Heating and hot water”, single energy-source mode, 1 supple-
mental electric heating, bivalence point -5°C

2

not for heat pumps with heating meters

3

not for heat pumps with heating meters

4

not for heat pumps with heating meters

5

not for heat pumps with heating meters

6

Heating/cooling version, single energy-source mode, 1 supplemental electric heating,
Bivalence point -5°C

7

Heating/cooling version, single energy-source mode, 1 supplemental electric heating, solar system,
bivalence point -5°C

8

not for heat pumps with heating meters

9

not for heat pumps with heating meters

10

Heating/cooling version, bivalent mode, bivalence point -3°C

11

Heating/cooling version, bivalent mode, solar system, bivalence point -3°C

12

Heating/cooling version, bivalent mode with solid fuel + option for 1 supplemental electric heating,
bivalence point -3°C

2. by operating mode

- single energy source

operation (supplemental
heating is a supplemental
electric heater)

- bivalent mode (supplemental

heating is a boiler)

3. by special case

- integration of solar systems

- integration of solid fuel boilers

The following pages show a selec-
tion of these basic hydraulic con-
figurations with the corresponding
basic programming list.

In any case, during commissioning,
assign one of the basic hydraulic
configurations via the menu item
system selection to the “On-site-
system”. Take special care that
the system you select is as near as
possible to system installed on-
site. The location of the sensors is
especially important. Please orient
yourself on the system diagram for
the selected system.

See page 24

The functions Heating circuit 2 (mixer circuit) and Hot water are automatically recognised through the
connected sensors when the heat pump manager is started up. The relevant menus are hidden if no sen-
sor is connected.