2600 Family Instruction Manual

52

Chapter 9 : Model 2620 Counter Module

Unlike most other IOM types in the 2600 family, nearly all of
the 2620-specific actions employ a special opcode format that
designates the counter channel to which the action applies.
The opcode byte that is issued to the 2620 is formed by adding
the counter channel number, multiplied by sixteen, to a base
opcode. For example, opcode 0x31 would be used to apply a
SetMode action (base opcode 0x01) to counter channel 3.

Note: Model 2620 has a maximum MRsp size of twenty bytes.

9.4.1 SetMode

Function

Programs a counter channel’s operating mode.

Opcode

0x00 + Chan * 16

Command

(Mode<7:0>),(Mode<15:8>)

Mode

is a 16-bit value, passed LSB first, that is

composed of bit fields that specify the functional
attributes of the counter channel.

Figure 45: Counter Mode MSB

RUN: Enable channel operations.

0 - (default upon module reset) Halt channel,

force core to zero (including bit 32), force
status bits to their default states, reset trigger
latches. Preload and latch registers are not
modified. After writing to the mode register
with this bit cleared, it is necessary to write
to it again with this bit set to start the channel
running.

1 - Run or continue to run in the specified

mode.

OM: Output pin’s mode (2-bit field):

0 - Counter bit 31.

1 - Counter bit 32 (toggles at zero counts).

2 - Active when counts are zero.

3 - Active during counter under/overflow.

XP: Index input polarity:

0 - Active high.

1 - Active low.

PL: Preload trigger (2-bit field):

0 - Preload on soft trigger only.

1 - Preload on index leading edge or soft

trigger.

2 - Preload on zero counts reached or soft

trigger.

3 - Reserved.

LAT: Latch trigger:

0 - Latch on soft trigger only.

1 - Latch on index leading edge or soft trigger.

CET: Count enable trigger:

0 - Enable upon configuration (no trig needed).

1 - Enable on index leading edge.

Figure 46: Counter Mode LSB

OP: Output pin’s polarity:

0 - Active high.

1 - Active low.

M: Mode (3-bit field). Modes 0-3 use
quadrature-encoded two-phase clock, modes 4-6
use single-phase clock, and mode 7 uses the
internal clock:

0 - quad x1, clock on rising A.

1 - quad x1, clock on falling A.

2 - quad x2, clock on either edge of A.

3 - quad x4, clock on either edge of A or B.

4 - mono, clock on rising A, B controls count

direction.

5 - mono, clock on falling A, B controls count

direction.

6 - mono, clock on either edge A, B controls

count direction.

7 - internal clock (10MHz), A is the gate

(enables counting while asserted), B controls
count direction.

CD: Count disable trigger:

0 - Never disabled by any trigger.

1 - Disable on index trailing edge (if enabled).

2 - Disable when zero counts reached.

PLM: Select preload register:

0 - Only preload register 0.

1 - Use both preload registers.

GetCountsTs

0x06

Return the channel’s count
with time stamp.

SetCommonControl

0x0F

Program the common
control register.

Parameter

Function

Mode

Collection of bit fields that specify the
counter’s functional attributes.

Table 27: Summary of 2620 Module Actions - Base Opcodes

Command

Opcode

Function

15

RUN

14

OM1

13

OM0

12

XP

11

PL1

10

PL0

9

LAT

8

CET

7

OP

6

M2

5

M1

4

M0

3

CD1

2

CD0

1

PLM

0

XC