Tape type <1>chg, Total calls, Appendix – Skutch Electronics CBC 9000 User Manual

Page 28: 24 hour time format, Trouble shooting, Reset system setup, Disconnect methods

Advertising
background image

Al Sandige

Page 28

12/05/01

SETTING is DIAL TO LISTEN. Press # to
continue.

TAPE TYPE <1>CHG

This parameter allows the user to select the type

of TRANSMITTER tape that you use. If you use a
leader type tape this parameter should be set to
LEADER TYPE. If you are using a leaderless tape,
then this parameter should be changed to
LEADERLESS. When LEADER TYPE is selected,
the unit automatically runs the TRANSMITTER
tape forward 7 seconds past the leader. It is
recommended that you use leaderless type tapes
because the leader type uses up about 7 1/2 seconds
of extra time for every answered call. To change
this selection press 1 and the type of tape will toggle.
The FACTORY SETTING is LEADERLESS. Press
# to continue.

Total Calls

After viewing the SETUP INFO press the #

key. Now the TOTAL CALLS will be displayed.
This is a GRAND TOTAL CALL COUNTER. It
shows the total calls that the machine has made. It
can be reset to zero by pressing 1 while the
SYSTEM is displaying the TOTAL CALLS. To
exit this mode press # and the unit will return to the
main menu.

Appendix

24 hour time format

The system uses 24 hour time format for the

internal clock.

! 12:00 a.m.

=

00:00

! 1:00 a.m. =

01:00

! 2:00 a.m. =

02:00

! 3:00 a.m. =

03:00

! 4:00 a.m. =

04:00

! 5:00 a.m. =

05:00

! 6:00 a.m. =

06:00

! 7:00 a.m. =

07:00

! 8:00 a.m. =

08:00

! 9:00 a.m. =

09:00

! 10:00 a.m.

=

10:00

! 11:00 a.m.

=

11:00

! 12:00 p.m.

=

12:00

! 1:00 p.m. =

13:00

! 2:00 p.m. =

14:00

! 3:00 p.m. =

15:00

! 4:00 p.m. =

16:00

! 5:00 p.m. =

17:00

! 6:00 p.m. =

18:00

! 7:00 p.m. =

19:00

! 8:00 p.m. =

20:00

! 9:00 p.m. =

21:00

! 10:00 p.m.

=

22:00

! 11:00 p.m.

=

23:00

Trouble shooting

This section has been provided to help the user

in case of problems. For best results, all of the
following procedures should be read and followed.
If after the following steps, you are still having
problems, go to the Customer Support section.

Reset System Setup

You can reset the system to the Factory defaults

by entering the following string:

RESET * # # # 1 * RESET

Disconnect methods

Once the unit detects an answer condition, it

activates the announcement portion of the system.
The announcement will play until it detects a
Disconnect condition. The following are the
disconnect systems incorporated into the CBC 9000.

The failure to detect a dialed digit within 5

seconds of a Consent code when in Play
mode.

CPC disconnect. The unit will disconnect

upon the detection of a CPC pulse that is
detected over the phone line. The CPC
pulse is generated by the telephone
company and is not available in all areas.
This is the ONLY form of disconnect that
will give immediate disconnect once the
called party hangs up.

The reception of 5 seconds of steady dial tone

during an incoming response period.

The detection of a pre-determined amount of

no response periods.

The detection of continuous speech for the

length of time set by the Voice Limit
parameter in the System Setup mode.

Advertising