47

OPTIONS #1

0) SEND BAR CODE TYPE ID

ON

Transmit the bar code identifier character at the

beginning of the bar code data. There is one space

between the ID character and the bar code data. The

identifier characters are defined below:

A CODE 39

B UPC-A

C UPC-E

D EAN-13

E EAN-8

F

INTERLEAVED 2 of 5

OFF *

Do not transmit BAR CODE TYPE ID.

1) DUPLICATE READS ALLOWED

ON *

Enable reading the same bar code multiple times.

OFF

Disable reading the same bar code twice in a row.

2) LASER / CCD TIMEOUT (0 - 9)

If the LASER or CCD has not read a bar code within the

designated time period, the device will be turned off. Select

from 0 to 9 seconds. The default is 1 second.

CAUTION: IF THE ABOVE OPTION IS SET AT ZERO (0)

SECONDS, IT WILL OVERRIDE THIS SAFETY

FEATURE.

3) LASER / CCD TRIGGER SHUTOFF

ON *

Releasing the trigger will turn off the LASER or CCD.

OFF

The LASER or CCD will continue to run until a

successful read or until the timeout period (from

option (2), LASER/CCD TIMEOUT) lapses.

NOTE:

To use "Blink Mode" with a CCD or laser, set

this option OFF, and set option (4), LASER/CCD

CONTINUOUS RUN, ON. (Note that "Blink

Mode" will not operate properly for lasers which

employ thermal shut-down.)

G

CODABAR

H

CODE 128

I

CODE 93

J

MSI/PLESSEY

K

CODE 11