10-7

whereas that of the system information sent from the information center to the other destinations is with

a precision of milliseconds.

sysname

Sysname is the system name of the current host. You can use the sysname command to modify the

system name. (For more information, see Basic System Configuration in the Fundamentals Command

Reference)

%%

This field is a preamble used to identify a vendor. It is displayed only when the output destination is log

host.

nn

This field is a version identifier of syslog. It is displayed only when the output destination is log host.

module

The module field represents the name of the module that generates system information. You can enter

the info-center source ? command in system view to view the module list.

level (severity)

System information can be divided into eight levels based on its severity, from 0 to 7. See

Table 10-1

for

definition and description of these severity levels. The levels of system information generated by

modules are predefined by developers, and you cannot change the system information levels. However,

you can configure to output information of the specified level using the info-center source command.

digest

The digest field is a string of up to 32 characters, outlining the system information.

For system information destined to the log host:

z

If the character string ends with (l), the information is log information

z

If the character string ends with (t), the information is trap information

z

If the character string ends with (d), the information is debugging information

For system information destined to other destinations:

z

If the timestamp starts with a %, the information is log information

z

If the timestamp starts with a #, the information is trap information

z

If the timestamp starts with a *, the information is debugging information

source

This field indicates the source of the information, such as the slot number of a board, IRF member ID,

IRF member ID and slot number, or the source IP address of the log sender. This field is optional and is

displayed only when the output destination is the log host.

content

This field provides the content of the system information.