Configuration prerequisites, Configuring udp echo tests – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 151

Advertising
background image

11-16

Configuration prerequisites

UDP echo tests require cooperation between the NQA server and the NQA client. Before you start UDP

echo tests, configure a UDP listening service on the NQA server. For more information about the UDP

listening service configuration, see

Configuring the NQA Server

.

Configuring UDP echo tests

Follow these steps to configure UDP echo tests:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter NQA test group view

nqa entry admin-name
operation-tag

Configure the test type as UDP
echo and enter test type view

type udp-echo Required

Configure the destination address
of UDP packets

destination ip ip-address

Required

By default, no destination IP
address is configured.

The destination address must be
the same as the IP address of the
listening service configured on the
NQA server.

Configure the destination port of
UDP packets

destination port port-number

Required

By default, no destination port
number is configured.

The destination port number must
be the same as that of the listening
service on the NQA server.

Configure the size of the data field
in each UDP packet

data-size size

Optional

100 bytes by default.

Configure the string to be filled in
the data field of each UDP packet

data-fill string

Optional

By default, the string is the
hexadecimal number
00010203040506070809.

Specify the source port of UDP
packets

source port port-number

Optional

By default, no source port number
is specified.

Configure the source IP address of
UDP packets

source ip ip-address

Optional

By default, no source IP address is
specified.

The source IP address must be
that of an interface on the device
and the interface must be up;
otherwise, no probe packets can
be sent out.

Configure optional parameters

See

Configuring Optional

Parameters for an NQA Test
Group

Optional