Configuring synchronous information output – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 129

Advertising
background image

10-15

z

To ensure that the AC works normally, use the info-center logfile size-quota command to set a

logfile to be no smaller than 1 MB and no larger than 10 MB.

z

Use the info-center logfile switch-directory command to manually configure the directory to

which a log file can be saved. The configuration will be invalid after system reboot.

Configuring Synchronous Information Output

Synchronous information output refers to the feature that if the user’s input is interrupted by system

output such as log, trap, or debugging information, then after the completion of system output the

system will display a command line prompt (a prompt in command editing mode, or a [Y/N] string in

interaction mode) and your input so far.

This command is used in the case that your input is interrupted by a large amount of system output.

With this feature enabled, you can continue your operations from where you were stopped.

Follow these steps to enable synchronous information output:

To do…

Use the command…

Remarks

Enter system view

system-view

Enable synchronous information
output

info-center synchronous

Required

Disabled by default

z

If system information, such as log information, is output before you input any information under the

current command line prompt, the system will not display the command line prompt after the

system information output.

z

If system information is output when you are inputting some interactive information (non Y/N

confirmation information), then after the system information output, the system will not display the

command line prompt but your previous input in a new line.

Disabling a Port from Generating Link Up/Down Logging Information

By default, all the ports of the AC generate link up/down logging information when the port state

changes. Therefore, you may need to use this function in some cases, for example:

z

You only concern the states of some of the ports. In this case, you can use this function to disable

the other ports from generating link up/down logging information.

z

The state of a port is not stable, and therefore redundant logging information will be generated. In

this case, you can use this function to disable the port from generating link up/down logging

information.